{"product_id":"rich-solar-nova-12k-12000-watt-48v-split-phase-hybrid-inverter","title":"RIch Solar NOVA 12K | 12000 Watt 48V Split Phase Hybrid Inverter","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThis split-phase hybrid inverter combines solar, battery, utility-grid, and generator power management in one unit for cabins, accessory dwelling units, tiny homes, residential properties, agricultural applications, and off-grid or grid-connected systems. It supports grid-tie, off-grid, and hybrid operating modes with pure sine-wave output.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor clarity, the unit accepts up to 12,000W of PV input and provides 10,000W of rated continuous AC output. It is offered in one configuration only, with no selectable product variants. Up to six identical units can be connected in parallel for expanded system capacity.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-Phase Output:\u003c\/strong\u003e Supports 120\/240V split-phase and 120\/208V split-phase configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Operating Modes:\u003c\/strong\u003e Supports grid-tie, off-grid, and hybrid operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Power Sources:\u003c\/strong\u003e Accepts solar PV, battery, utility-grid, and generator inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Coupling:\u003c\/strong\u003e Built-in AC-coupled functionality supports system integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Expansion:\u003c\/strong\u003e Supports parallel operation of up to six identical units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure Sine-Wave Output:\u003c\/strong\u003e Produces pure sine-wave AC power with 91% DC-to-AC efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Monitoring:\u003c\/strong\u003e Built-in Wi-Fi supports real-time monitoring through a mobile application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Communication:\u003c\/strong\u003e RS485 connectivity supports battery-management-system integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Energy Monitoring:\u003c\/strong\u003e Uses an external CT sensor to support 100% self-consumption control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Breakers:\u003c\/strong\u003e Includes an integrated 300A DC breaker and 60A AC breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc-Fault and Rapid-Shutdown Functions:\u003c\/strong\u003e Includes AFD and RSD functions associated with NEC 690.11 and NEC 690.12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Detection:\u003c\/strong\u003e Provides ground-fault detection associated with NEC 690.5.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV Protection:\u003c\/strong\u003e Includes PV-input lightning protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor-Rated Enclosure:\u003c\/strong\u003e IP65-rated enclosure supports indoor or outdoor installation when installed according to the official manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Configuration:\u003c\/strong\u003e No selectable size, voltage, bundle, or quantity options are shown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV Input Power:\u003c\/strong\u003e 12,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated AC Output Power:\u003c\/strong\u003e 10,000VA \/ 10,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum DC Voltage:\u003c\/strong\u003e 600VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal DC Voltage:\u003c\/strong\u003e 360VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking DC Voltage Range:\u003c\/strong\u003e 120–550VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStartup Voltage:\u003c\/strong\u003e 125VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Feeding Voltage:\u003c\/strong\u003e 160VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPPT Voltage Range:\u003c\/strong\u003e 120–550VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPPT Inputs:\u003c\/strong\u003e Dual inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV Input Current:\u003c\/strong\u003e 2 × 18A, 30A peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV Short-Circuit Current:\u003c\/strong\u003e 2 × 18A, 30A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Backfeed Current to PV Array:\u003c\/strong\u003e 0A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Output Voltage:\u003c\/strong\u003e 120VAC phase-to-neutral; 208VAC or 240VAC phase-to-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 105.5–132VAC per phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Output Current:\u003c\/strong\u003e 41.7A per phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Frequency:\u003c\/strong\u003e 50Hz or 60Hz, auto-sensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Frequency Range:\u003c\/strong\u003e 47.5–51.5Hz or 59.3–60.5Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Waveform:\u003c\/strong\u003e Pure sine wave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-to-AC Efficiency:\u003c\/strong\u003e 91%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor Range:\u003c\/strong\u003e 0.9 leading to 0.9 lagging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current and Duration:\u003c\/strong\u003e 50A per phase for 20 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Fault Current and Duration:\u003c\/strong\u003e 90A per phase for 1 millisecond\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Overcurrent Protection:\u003c\/strong\u003e 90A per phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Startup Voltage:\u003c\/strong\u003e 85VAC per phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Auto-Restart Voltage:\u003c\/strong\u003e 90VAC per phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcceptable AC Input Voltage Range:\u003c\/strong\u003e 85–140VAC per phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Power:\u003c\/strong\u003e 10,000VA \/ 10,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum AC Input Current:\u003c\/strong\u003e 60A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Inrush Current:\u003c\/strong\u003e 60A for 1 millisecond\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Battery Voltage:\u003c\/strong\u003e 48VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery DC Voltage Range:\u003c\/strong\u003e 40–62VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Battery Discharge Current:\u003c\/strong\u003e 200A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Solar Charging Current:\u003c\/strong\u003e 200A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum AC Charging Current:\u003c\/strong\u003e 200A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Combined Charging Current:\u003c\/strong\u003e 200A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Capability:\u003c\/strong\u003e Up to six units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated DC Breaker:\u003c\/strong\u003e 300A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated AC Breaker:\u003c\/strong\u003e 60A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Class:\u003c\/strong\u003e Class I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -13°F to 140°F, with power derating above 113°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0–90% relative humidity, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Altitude:\u003c\/strong\u003e Approximately 6,562 ft; power derates by 1% for every approximately 328 ft above approximately 3,281 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS232, RS485, Wi-Fi, and USB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 112 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications and Compliance:\u003c\/strong\u003e UL 1741SA\/SB, CSA C22.2 No. 107.1, IEEE 1547, CEC-listed, FCC Part 15 Class B, California Rule 21, and HECO Rule 14H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (D × W × H):\u003c\/strong\u003e 8.5 × 20.3 × 28.1 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Installation Clearance:\u003c\/strong\u003e Approximately 19.7 in at each side, above, and below; approximately 39.4 in in front\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible With:\u003c\/strong\u003e Lead-acid, lithium-ion, and nickel-cadmium battery systems operating within the specified 40–62VDC battery range; single-crystalline and polycrystalline solar modules; utility-grid and generator inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot Compatible With:\u003c\/strong\u003e PV module types other than single-crystalline and polycrystalline modules, as stated in the official manual.\u003c\/p\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne hybrid inverter unit\u003c\/li\u003e\n\u003cli\u003eOne RS232 cable\u003c\/li\u003e\n\u003cli\u003eOne parallel cable\u003c\/li\u003e\n\u003cli\u003eCurrent-sharing wires\u003c\/li\u003e\n\u003cli\u003eOne external CT sensor\u003c\/li\u003e\n\u003cli\u003eOne user manual\u003c\/li\u003e\n\u003cli\u003eOne software CD\u003c\/li\u003e\n\u003cli\u003eFixing screws\u003c\/li\u003e\n\u003cli\u003eOne Wi-Fi antenna\u003c\/li\u003e\n\u003cli\u003eOne wall-mount bracket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"pf0\"\u003e\u003cspan class=\"cf0\"\u003eProduct Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"pf1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0905\/1868\/3895\/files\/NOVA_12K-Specification-Premium-250521_d8a9603a-fa3f-451e-80cc-2122f6745b88.pdf?v=1786276996\"\u003e\u003cspan class=\"cf0\"\u003eSpecifications\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"pf1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0905\/1868\/3895\/files\/NOVA_12K-Manual-20250507.pdf?v=1786277009\"\u003e\u003cspan class=\"cf0\"\u003eOwner's Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0905\/1868\/3895\/files\/E547316-vol1-MLCertificateofCompliance-E553290.pdf?v=1786171916\"\u003e\u003cspan class=\"cf0\"\u003eUL Certification\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rich Solar","offers":[{"title":"Default Title","offer_id":51009186660599,"sku":"RS-H12K","price":2999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0905\/1868\/3895\/files\/nova-12k-12000-watt-48-volt-split-phase-hybrid-inverter-3.jpg?v=1786277098","url":"https:\/\/northgridsupply.com\/products\/rich-solar-nova-12k-12000-watt-48v-split-phase-hybrid-inverter","provider":"Northgrid Supply","version":"1.0","type":"link"}