{"product_id":"ruixu-self-heating-server-rack-battery-daisy-chain-bracket-rack-cec-sgip","title":"RUiXU Self-heating Server Rack Battery | Daisy Chain | Bracket Rack | CEC | SGIP","description":"\u003cp\u003eThis self-heating server-rack battery kit provides modular lithium iron phosphate energy storage for residential applications. Available 10kWh, 15kWh, and 20kWh configurations use compact 3U battery modules and support bracket-rack daisy-chain installations.\u003c\/p\u003e\n\u003cp\u003eEach module supplies 5.12kWh of nominal energy. The system supports up to 32 modules in parallel, allowing expansion from 5kWh to 160kWh without an external controller.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Heating System:\u003c\/strong\u003e Integrated heater pads draw power from the charger to support battery heating in cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Heater Control:\u003c\/strong\u003e Self-heating starts at or below 41°F and stops at or above 53.6°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Expansion:\u003c\/strong\u003e Supports up to 32 battery modules in parallel for configurations from 5kWh to 160kWh without an external controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Supports wall-mounted, floor-mounted, stacked, and rack-mounted installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBracket-Rack Configuration:\u003c\/strong\u003e Supports compact vertical stacking using optional bracket kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Battery Management:\u003c\/strong\u003e Provides over-discharge, overcharge, overcurrent, and cell-balancing protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchscreen Interface:\u003c\/strong\u003e A 5-inch capacitive touchscreen displays battery information and allows battery settings to be adjusted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Selection:\u003c\/strong\u003e DIP addressing allows configuration of the RS485 baud rate and inverter protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Protection:\u003c\/strong\u003e A perfluorohexane module improves protection for internal electrical lines and battery cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTool-Free Connections:\u003c\/strong\u003e Quick plugs provide 250A continuous overcurrent capacity with tool-free connection, anti-loosening, and heating protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Pole Protection:\u003c\/strong\u003e Uses a negative-terminal fuse and positive-terminal micro circuit breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Access:\u003c\/strong\u003e A side inspection port provides access to the battery-management system and fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRust-Resistant Enclosure:\u003c\/strong\u003e Electro-coated battery-case construction provides rust protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell Chemistry:\u003c\/strong\u003e Lithium iron phosphate (LiFePO4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 51.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Capacity:\u003c\/strong\u003e 100Ah\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Energy per Module:\u003c\/strong\u003e 5.12kWh\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsable Energy per Module:\u003c\/strong\u003e 4.92kWh\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e 44.8-56.0V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge Voltage:\u003c\/strong\u003e 56V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat Voltage:\u003c\/strong\u003e 54.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Charge Current:\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Charge Current:\u003c\/strong\u003e 70A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Discharge Current:\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Discharge Current:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Discharge Current:\u003c\/strong\u003e 101-119A for 5 minutes; 120-149A for 15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS485 and CAN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle Life:\u003c\/strong\u003e At least 6,000 cycles at 90% depth of discharge under specified test conditions; at least 9,500 cycles at 80% depth of discharge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign Life:\u003c\/strong\u003e 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 14°F-122°F; derating applies from 14°F-50°F and 104°F-122°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e 14°F-113°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5%-90%, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Installation Altitude:\u003c\/strong\u003e Approximately 13,123 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Location:\u003c\/strong\u003e Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Methods:\u003c\/strong\u003e Wall-mounted, floor-mounted, stacked, and rack-mounted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Capacity:\u003c\/strong\u003e Up to 32 modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Capacity Range:\u003c\/strong\u003e 5kWh-160kWh\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeater Voltage:\u003c\/strong\u003e 56V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeater Power Consumption:\u003c\/strong\u003e 480W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Heating Start Temperature:\u003c\/strong\u003e At or below 41°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Heating Stop Temperature:\u003c\/strong\u003e At or above 53.6°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL 9540A, CE, IEC 62619, UL 1973, and UN 38.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed Programs:\u003c\/strong\u003e CEC and SGIP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Format:\u003c\/strong\u003e 19-inch rack-mounted, 3U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 18.9 x 5.2 x 18.1 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e Approximately 103.6 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Bracket-Rack Capacity:\u003c\/strong\u003e Up to nine modules vertically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCAN Communication:\u003c\/strong\u003e Victron, SMA, Studer Innotec, Sofar, Sol-Ark, Solis, GoodWe, Deye, Growatt, SAJ, LuxPower, Megarevo, INVT, Sermatec, TBB, MUST, Sunsynk, and Schneider\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRS485 Communication:\u003c\/strong\u003e MPP, Voltronic, RCT, Alpha, and OutBack\u003c\/p\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cp\u003ePer battery:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e(1) self-heating 48V server-rack battery\u003c\/li\u003e\n\u003cli\u003e(1) RJ45\/CAT5e patch cable\u003c\/li\u003e\n\u003cli\u003e(1) ground cable\u003c\/li\u003e\n\u003cli\u003e(1) set of parallel 4AWG cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRS485 computer communication cable for battery monitoring and firmware updates\u003c\/li\u003e\n\u003cli\u003eInverter communication cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0905\/1868\/3895\/files\/5a8653_caa269d8f9d94896be47148a2e33697f_1_ae1dde61-c249-4641-9edc-0ad54e4093bb.pdf?v=1785236878\"\u003eOwner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0905\/1868\/3895\/files\/5a8653_7483a6ec226f4eb99c84f582a8d42cd5_1_3ec83d66-11e5-4d03-9ef7-aac67990260a.pdf?v=1785236897\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ruixu","offers":[{"title":"15kWH","offer_id":50979761127671,"sku":"RX-LFP48100-H-BR-15K","price":2348.0,"currency_code":"USD","in_stock":true},{"title":"20kWH","offer_id":50979761160439,"sku":"RX-LFP48100-H-BR-20K","price":2348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0905\/1868\/3895\/files\/2_f4b2edb3-4f4d-4071-8085-98e5cc13a3ea.png?v=1785236826","url":"https:\/\/northgridsupply.com\/products\/ruixu-self-heating-server-rack-battery-daisy-chain-bracket-rack-cec-sgip","provider":"Northgrid Supply","version":"1.0","type":"link"}